SW2MS Series
Copied to clipboard
SW2MS-RL
- Product Feature
Roller Lever Type
- Dimension
68(W)×88.5(H)×171(L)
- Materials
Body, Head, Bolt & Nut, Roller, Spring Rod-Stainless Steel
- Protection rating
IP67
- Certificate
※ Please refer to technical information page for detailed specification including measurement.
(PDF Viewer, PDF Download, Auto-CAD)
Product Feature
Product Feature- Robust structure featuring a body and head made of STS316L stainless steel, offering exceptional corrosion and salt resistance, ideally suited for marine and chemical gas environments
High mechanical strength effectively absorbs irregular dog motions transmitted to the actuator, ensuring more stable operation
Stable operational characteristics maintained even after prolonged use, achieved through our proprietary dual-return spring system
Superior corrosion resistance demonstrated in harsh polar and offshore conditions by employing stainless steel (STS) external bolts, nuts, and components
Typical applications: Overhead cranes, large-scale conveyors, heavy industrial machinery Outdoor plant facilities, ship deck machinery, port cargo handling equipment Chemical plants with corrosive acidic or alkaline gases present
Customizable low-temperature type (-40℃ to +40℃) and high-temperature type (+50℃ to +120℃) available upon request
Product Specifications
| Protection Grade | IP66 | |
|---|---|---|
| Mechanical Life | Over 2 million operations | |
| Electrical Life | Over 0.2 million operations | |
| Allowable Operating Cycle | Mechanical | 120 operations per minute max. |
| Electrical | 30 operations per minute max. | |
| Insulation Resistance | 100MΩ min. at 500V DC | |
| Contact Resistance | 50MΩ max. | |
| Dielectric Strength | Between Non-continuous Terminals | 1,000VAC, 50 to 60Hz for 1 minute |
| Between Each Terminal and Non-conducting Metal Part | 2,000VAC, 50 to 60Hz for 1 minute | |
| Shock Resistance | Destruction | Approx. 1,000m/s² (100G) |
| Malfunction | Approx. 250m/s² (25G) | |
| Vibration Resistance | 10 to 55Hz, 1.5mm double amplitude | |
| Allowable Operating Temperature Range | -10℃ to +55℃ -40℃ to +40℃ (Cold-Resistant Type) +50℃ to +120℃ (Heat-Resistant Type) | |
| Ambient Humidity Range | 45 ~ 85% RH | |
| Certificate | ||
| Inrush Current | NC (Normally Closed) | Max. 20A |
|---|---|---|
| NO (Normally Opened) | Max. 10A |
* Annotation
1. The figures in the diagram represent normal current.
2. The inductive load has a power factor of 0.4 or higher (AC) and a time constant of 7ms or less (DC).
3. The lamp load is assumed to have 10 times the inrush current.
4. The motor load current is assumed to have 6 times the inrush current.